8077-F
Software is not bundled with this product. Please confirm that the program you select will operate properly according to the communication
protocol and conditions listed below. ID data is stored in ROM and therefore will not be cleared when the unit is turned off.
٨
Do not use excessive force when inserting a wire into the wire insert point. Damage may result to the terminal or product.
Caution
3.How to use (ASCII command requirements)
Communication protocol
@ ޓ? ޓ? ޓ1 ޓ2 ޓ> ޓ!
Header ID1 ID2
Command
Data1 Data2
End code
Header
㧬㨇40H
End code
!21H
ID
Command
030H㨉̖ActionOFF
131H㨉̖ActionON
? [3FH] --- Create or change ID
Data
٨Command to operate 1-8 outputs
٨Command to set ID # when ID is used (optional)
This example operates switches # 6,4,3 and2.
Programming example as above executes the commands set on No.6,4,3 and 2.
Example input
Letter
(
ASCII code
)
Bit data
Action No.
Data1
232H
00110010
8765
Data2
>3EH
00111110
4321
1 bite
2 bite
1 bite
2 bite
1 bite
The default ID is ?? [3FH 3FH].
In this case, the unit does not use an ID.
Examples
Serial communication specification
Reply code
Header ID1 ID2
command
Data1 Data2
End code
??108
40H 3FH 3FH 31H
30H 38H
21H
ASCII code
HEX code
٨To excute the command of No.4 on
00110000B 00111000B
Header ID1 ID2
command
Data1 Data2
End code
??0??
40H 3FH 3FH 30H
3FH 3FH
21H
ASCII code
HEX code
٨To cancel all the commands
00111111B 00111111B
Header ID1 ID2
command
Data1 Data2
End code
23?46
40H 32H 33H 3FH 34H 36H 21H
ASCII code
HEX code
٨
To change ID of PHC-100A from 23[32H*33H] to 46[34H*36H]
Communication specification
RS-232C compliant
Communication speed
9600bps
Data length 8 bit
Stop bit 1 bit
Parity Any setting
Any setting
synchronous mode
Flow control
Synchronous mode
Transmission mode Half-duplex mode
Transmission code ASCII code
Reply code
ACK06H
NACK15H
̪The product d
oes not work if a command is sent before ACK(06H) is replied.
Reply code
E㨞㨞㨛㨞 contents
When a command, other than 0[30H], 1[31H] or ?[3FH], is set
When data, other than 0[30H] - ?[3FH], is used
Reply interval between data is
more than 5 seconds after receipt of header
Transmission condition
ACK06H
When data transmission is finished
NACK15H
Command error
Data error
Timeout
Connect the (straight) cable DSUB9P (female) connector to the PHC-100A communications port.
Connect the other end of the cable to your PC or DTE device
̪
عPHC-100A ع㧼㧯
Refer to instructions manual of PC
when connecting this product to
PC with RS-232C straight cable.
AC adaptor
120V AC
ASCII code
Hex 0 1 2 3 4
0 NUL DLE Space 0 @
1 SOH DC1 ! 1 A
2 STX DC2 " 2 B
3 ETX DC3 # 3 C
4 EOT DC4 $ 4 D
5ENQNAK% 5 E
6 ACK SYN & 6 F
7 Bell ETB ' 7 G
8 BS CAN ( 8 H
9HTEM) 9 I
A LF SUB * : J
B VT ESC + ; K
CFFFS , < L
DCRGS - = M
ESORS . > N
FSIUS/ ?O
Higher code
Lower code
Connection cable
Signal
PHC-100A
Shield
Pin No.
FG -
TXD 3
RXD 2
RTS 7
CTS 8
SG 5
Signal
PC
Data output
Pin No.
-1
32
23
74
85
57
FG
TXD
RXD
RTS
CTS
SG
D-SUB9P D-SUB25P
D-SUB9P
عReset switch
All commands can be reset by pressing a reset switch.
While the reset switch is pressed, this product does not
accept any communication commands, and then, CTS line of
RS-232C will be at low level.
3.Wiring example
The internal contacts are non-voltage contacts (relay contact). They operate products which contact capacity is under AC125V3A or DC30V3A.
The products having the different voltage can be connected to each contact, since each contact is independent.
̪The example listed above is in the case of the 120V AC product. The direct current product of DC 30V or less also can be connected.
RS-232C Straight cable
Power operatingIn the case of products operated by power supply(When the 120V AC product is used)
عWiring example 1
AC adaptor connection
٨Block diagram٨Wiring diagram
ψ120V AC
120V AC φ
120V AC
PC
RS-232C Straight
cable
< Warning lights etc. >
PHC-100A
AC adaptor
(bundled)
PC
PHC-100A
PC
PHC-100A
RS-232C straight
cable
RS-232C Straight
cable
120V ACޓ
φ
AC adaptor connection
Signal light
Audible alarms
etc.
lead wire 1
lead wire 2
lead wire 3
COM wire
ψ 120V AC
1.Wiring to the terminal block
2.Connecting the RS-232C cable (Not supplied with the PHC-100A)
٨Terminal block
٨How to make wiring connection
Ԙ Strip the wire insulation back 9 mm ԙ Depress the connect-disconnect lever with a slotted screwdriver
Ԛ While holding the lever depressed, insert the wire
ԛ Remove the screwdriver to and check that the wire does not come out easily
Connect-disconnect lever operation A slotted screwdriverޓnominal size 4.5mm50mm
Applecable wire
9mm
A solid wireޓǾ0.4㨪Ǿ1.2mm AWG2618
A twisted wireޓ0.30.75mmޓ㧔AWG2220
̪When using stranded wire, the strand should be more than 0.18 mm diameter.
2
A slotted screwdriver
9mm
Connect-disconnect lever
Wire insert point
120V AC
120V AC
Warning
lights
RELAY
No.8
Lead wire operating : In the case of products operated by lead wire. (When the 120V AC product is used)
عWiring example 2
٨Block diagram
٨Wiring diagram
AC adaptor
(bundled)
PC
PHC-100A
120V AC
Signal
light
RELAY
No.8
RELAY
No.7
RELAY
No.6
ធὐኈ㊂
ޓޓޓޓޓޓޓ
߹ߢ
Contact capacity
125V AC,3A
30V DC,3A
87654321
࡝࡟࡯ធὐNo.(Relay contact No.)
㔚✢ⵍⷒ೸߈㐳ߐ㧦9mm(Strip)
න✢:
Ǿ
0.41.2mm(Single wire)
᠐✢:0.30.75mm
2
(Twist wire)
MODEL
PHC-100A
Reset switch
RS-232C
Power
24V DC
૶↪น⢻㔚✢
Applicable wire
Strip length
㧙㧞㧙 㧙㧟㧙